We are Craig and Mary, a brother and sister who run Sisu Research Supply. Craig is an electrical engineer, and he likes numbers you can check. Here is what we test, who tests it, and how to check the paperwork.
Section 1: How we test
Who does the testing
- Freedom Diagnostics, an independent third-party lab, tests every listed batch.
- Lab accessories, such as SISU Research Water, are not part of this test panel and do not have COAs.
- Samples are hand-delivered to the lab, for chain of custody.
- Each tested batch has its own COA.
The panel
The panel covers identity, quantity (mg), HPLC purity, endotoxin (LAL), microbial screen (PCR), elemental impurities (ICP-MS), and fentanyl.
- Identity: The lab uses LC-MS to measure the sample's ions and reports whether the compound's identity is confirmed.
- Quantity (mg): The measured milligrams in the vial.
- HPLC purity: Purity is reported as the share of the target compound peak or peaks among all detected peaks.
- Endotoxin (LAL): An LAL screen of the sample for bacterial endotoxin.
- Microbial screen (PCR): A PCR screen of the sample for microbial DNA.
- Elemental impurities (ICP-MS): An ICP-MS screen for a panel of elements.
- Fentanyl: A screen that reports whether fentanyl was detected.
Endotoxin and microbial results are material-quality screens on the sample as tested by the lab.
Purity and quantity
- Purity and quantity come from 3 vials per batch, and the COA library shows each vial's result and the average.
- Two extra vials per batch are tested for quantity and purity conformity.
- Each vial result describes the vial the lab tested.
Blends
- Each component is tested and reported separately.
- HPLC purity is reported as one figure for the whole vial.
Section 2: How to read a Sisu COA
Work down the COA in this order. Bracketed numbers match the labels on the COA image.
Example: a real Sisu COA (GHK-Cu 50 mg, lot SISU-GHK50-2607-01)
- 1
Step 1: Match the lot number [1]
- Match the batch number on your vial label to the Lot field on the report, character by character.
- Our lot numbers include letters, so watch O and 0, and I and 1.
- On the example COA: Lot: SISU-GHK50-2607-01. The vial label reads Batch: SISU-GHK50-2607-01.
- 2
Step 2: Check the lab name and report date [2]
- The report should name Freedom Diagnostics as the lab. The sample is received first, then reported.
- Enter the Search Code on the lab's own website to pull up the lab's copy, then compare it with ours, field by field.
- The lot number, lab name, and dates in our library should match the COA PDF. If they don't, tell us.
- On the example COA: Freedom Diagnostics (FreedomDiagnosticsTesting.com). Client: Sisu Research Supply LLC. Accession #: 2607270401. Search Code: Sisu2607270401. Received: 7/27/2026. Reported: 7/30/2026.
- 3
Step 3: Read the identity result [3]
- In the Mass Confirmation spectrum, each labeled peak is an observed ion, marked with compound name and charge state. [M+2H]2+ reads at roughly half the [M+H]+ value; both point to the same molecule.
- On the example COA: Identity: Confirmed. Identity (LC-MS): GHK-Cu. Mass Confirmation: GHK-Cu [M+H]+ at 341.300 and GHK-Cu [M+2H]2+ at 171.300. Method: HPLC with UV detection coupled with mass spectrometry (LC-MS).
- 4
Step 4: Read the quantity in mg [4]
- Net Content is the measured mg in each tested vial. Measured mg can read above or below the label amount.
- On the example COA (label: GHK-Cu 50mg): Vial 1: 57.83 mg. Vial 2: 55.94 mg. Vial 3: 54.06 mg. Net Content: 55.94 mg (shown in our library as the 3-vial average).
- 5
Step 5: Read the HPLC purity [5]
- Purity comes from the Chromatogram. It is separate from identity (Step 3) and mg (Step 4).
- On the example COA: Vial 1: 99.79%. Vial 2: 99.78%. Vial 3: 99.79%. Purity (HPLC-UV): 99.79% (shown in our library as the 3-vial average). The chromatogram shows one labeled peak, GHK-Cu.
- 6
Step 6: Read the material-quality screens [6]
- Endotoxin Threshold: Pass. Endotoxin Replicate 1: Pass. Endotoxin Replicate 2: Pass.
- Microbial Analysis (PCR): Pass. Microbial Analysis (PCR): No Detectable Microbial DNA.
- 7
Step 7: Read the elemental impurities result [7]
- Elemental Impurities (ICP-MS): Pass (As | Cd | Pb | Hg).
- 8
Step 8: Read the fentanyl result [8]
- Fentanyl: No Fentanyl Detected.
- 9
Step 9: For blends, read each component [9]
- Check the identity and quantity lines for every component, as in the blend example below.
Reading a blend COA
Example: a real Sisu blend COA (BPC-157/TB-500 20mg, lot SISU-BB20-2607-01)
How the components make up one vial
- This vial holds BPC-157 and TB-500 together. The label reads 20MG (10MG/10MG), meaning 10 mg of each.
- Each component is tested and reported separately.
- The lab measures each component's mg on its own in each of the 3 vials. The COA does not report one combined mg figure.
- Our library lists tested mg for each component in each vial, as reported on the COA.
- The component averages add to 22.30 mg (10.74 plus 11.56) against a 20 mg label.
The blend COA, field by field
- Lot [B1]: SISU-BB20-2607-01. The vial label reads BATCH: SISU-BB20-2607-01.
- Lab and dates [B2]: Freedom Diagnostics. Accession #: 2608100417. Search Code: Sisu2608100417. Received: 8/10/2026. Reported: 8/13/2026.
- Identity [B3]: Identity: Confirmed. Identity (LC-MS): TB-500/BPC-157. Mass Confirmation shows TB-500 [M+2H]2+ at 445.200, a TB-500 [M+H]+ label over the peaks marked 889.300 and 890.300, and BPC-157 [M+2H]+2 at 710.300.
- Net Content per vial [B4]: Vial 1: TB-500: 10.82 mg, BPC-157: 10.44 mg. Vial 2: TB-500: 11.66 mg, BPC-157: 10.69 mg. Vial 3: TB-500: 12.19 mg, BPC-157: 11.10 mg.
- Net Content, Analytical Results [B4]: TB-500: 11.56 mg. BPC-157: 10.74 mg. These equal the average of each component's 3 vial results on the COA.
- Purity [B5]: Vial 1: 99.17%. Vial 2: 99.13%. Vial 3: 99.15%. Purity (HPLC-UV): 99.15% (shown in our library as the 3-vial average). The chromatogram shows two labeled peaks, TB-500 and BPC-157.
- Material-quality screens [B6]: Endotoxin Threshold: Pass. Microbial Analysis (PCR): Pass.
- Elemental impurities [B7]: Elemental Impurities (ICP-MS): Pass (As | Cd | Pb | Hg).
- Fentanyl [B8]: No Fentanyl Detected.
- Each component [B9]: separate mg lines, peaks and spectra for TB-500 and BPC-157.
Find any lot in the COA library
- Our COA library is public, and no account is needed: www.sisuresearch.com/coa-library.
- Find your batch number, open its COA, and run the nine steps. We would rather you check us than take our word for it.
FAQ
Why do you use an independent lab?
A lab with no stake in the result gives you a different kind of document from a seller's own bench test. That is why we use Freedom Diagnostics, an independent third-party lab. Samples are hand-delivered to the lab.
What if my lot isn't in the library?
First, check the lookalike characters, such as O and 0, or I and 1. If you still can't find it, email info@sisuresearchsupply.com or text (615) 863-9600 with your lot number and we will sort it out.
Research materials only. Not for human or animal use.